Infrared Imaging Temperature Measuring Wind Speed Measurement Gas Detection Multifunctional Detector HRYXJ-A
Contact Person : Tina Yu
Phone Number : 86-10-57621296
WhatsApp : +8613683015302
Detail Information |
|||
Size: | 270*210*120mm | IP Grade: | IP55 |
---|---|---|---|
A Battery Working Time: | 48h | OWorking Current: | 250mA |
Power: | 5000mAH Li-battery, Overloaded Protection | Detection Range: | 500m |
High Light: | hand held gas detector,portable gas detection equipment |
Product Description
1.Overview
IR119 wireless Multi-gas detector is one gas detector which can detect poisonous gas ,oxygen and toxic gas in demanding industry environment. It can take wireless remote data transmission. With built-in module, one wireless receiver PAD can simultaneously take data acquisition and control from several IR119 gas detectors. It also can provide real time monitoring information and give out alarm signal when the gas concentration exceeds the standard. With stainless steel housing, and higher protection grade ,IR119 has a excellent performance in harsh environment.
2.Applications:
Widely used in mine, tunnel ,underground pipe ,the fire department emergency rescue monitoring and hazardous chemical detection.
3.Features:
Built-in powerful sampling pump
Customized alert point
2000 groups data storage ability
Transferred by WIFI,GPRS or RS232
Imported sensors and replaceable modular sensor
All detection data can be displayed simultaneously on the wireless receiver
Two power supply ways, Lithium battery and DC power.
Easy operation and reliable.
4. Detect range
Detect gas | Range | Intrinsic Error | Alert | Response time |
CO | (0~20)×10-6 CO | ±2×10-6CO |
Alert set range: 25×10-6 CO~100×10-6CO Alert :24×10-6 CO Alert Error:±1×10-6 CO |
45s |
(20~100)×10-6 CO | ±4×10-6CO | |||
(100~500)×10-6 CO | ±5% | |||
(500~1000)×10-6 CO | ±6% | |||
CH4 | (0.00~1.00)% CH4 | ±0.10%CH4 |
Alert set range: 0.5%CH4~4.00%CH4 Alert:1.00% CH4 Alert Error:±0.05% CH4 |
20s |
(1.00 ~3.00)% CH4 | ±10% | |||
(3.00~4.00)% CH4 | ±0.30%CH4 | |||
O2 | (0~5.0)% O2 | ±0.5%O2 |
Alert set range: 16% O2~19.5% O2 Alert:18% O2 Alert Error:±0.1% O2 |
35s |
(>5.0~25.0)% O2 | ±3.0%FS | |||
H2S | (0~49)×10-6H2S | ±3×10-6 H2S |
Alert set range: 5×10-6 H2S~15×10-6H2S Alert:10×10-6 H2S Alert Error:±3×10-6 H2S |
45s |
(50~100)×10-6 H2S | ±10% | |||
SO2 | (0~30)×10-6SO2 | ±3×10-6SO2 |
Alert:10×10-6SO2 Alert Error:±1×10-6SO2 |
45s |
(30~60)×10-6SO2 | ±10 % |
5.Specification
Detection range | 500m |
Power | 5000mAH Li-battery, overloaded protection |
Working current | 250mA |
Battery working time | 48h |
IP Grade | IP55 |
Size | 270*210*120mm |
Enter Your Message